              2. Welcome to Beijing Airport Beiguang Instruments Co., Ltd
                        
                Your Current Location :HomeF56 VA Flowmeter  ? F56/P8L VA Flowmeter
                F56/P8L  VA Flowmeter

                Name:F56/P8L VA Flowmeter

                Details


                Features

                ◆ Designed for food industry.

                ◆ Easy to disassemble, clean and maintain.

                ◆ Housing made of stainless steel, corrosion resistant.

                ◆ Indicator made of stainless steel by stamping forming, surface polished, beautiful and compact structure.

                ◆ Local display indicator and local display with transmitter indicator are optional to meet a variety of control requirements.

                ◆ Varieties of nominal diameter are available up to DIN3276(I SO2852, ASME and so on).

                ◆ Standard clamp connection.

                ■ Current output specification 

                Power supper: (12 to 36) VDC 

                Rated voltage: 24VDC

                Output signal: (4 to 20) mA/HART protocol remote signal.

                Type

                F56Food Industrial Level

                Fluid type

                Liquid, gas, steam

                Flow rangeConvert to standard medium, 100% values

                Water20

                (10 to 100000) L/hSpecial order according to user requirements

                Air0.1013MPa20

                (0.7 to 3000)Nm3/hSpecial order according to user requirements

                Rangeability

                101

                 

                 

                 

                Indication accuracy

                 

                 

                Local type

                Mechanical pointer indication

                1.52.54.0(F.S. as standart)

                Digital display (battery powered, service life 1 years)

                1.52.54.0(F.S. as standart)

                Transmitter: simultaneous pointer indication and digital display

                1.52.54.0(F.S. as standart)

                 

                 

                 

                Fluid temperature

                 

                 

                Local type

                Mechanical pointer indication

                ‐80to +200℃(PTFE:0 to 80

                Digital display (battery powered, service life 1 years)

                ‐40to +120℃(PTFE:0 to 80High temperature type 200

                Transmitter: simultaneous pointer indication and digital display

                ‐40to +120℃(PTFE:0 to 80High temperature type 200

                 

                 

                 

                 

                Ambient temperature

                 

                 

                Local type

                Mechanical pointer indication

                ‐40to +120

                Digital display (battery powered, service life 1 years)

                 

                ‐20to +60

                Transmitter: simultaneous pointer indication and digital display

                 

                ‐20to +60

                Fluid viscosity

                DN1510 to 25(l/h) η<1 mPa.s, >25(l/h) η<5 mPa.s; DN25η<20 mPa.s; DN50 to 250η<30 mPa.s

                 

                Fluid pressure

                DN15DN50

                4.0MPa

                DN80DN250

                1.6MPa

                Process connection

                Sanitary clamp (standard: DIN32676; ISO2852); sanitary union(standard: DIN11851; SMS1145)

                Electrical connection

                M12 electrical connector

                Installation(Flow direction)

                Vertical flow direction (bottom→toptop→bottom); Horizontal flow direction (lift→rightright→lift)

                Installation conditions

                Inlet section ≥ 5 × DN, outlet section ≥ 3 × DN

                Protection category

                IP65(Other orders need to be explained separately

                 

                Ex‐mark

                Ex ia II C T4 to T6 Ga

                Ex d II C T6 Gb

                Intrinsically safe data

                Ui=28V Ii=93mA Pi= 0.65W Ci≤ 5nF Li =0mH

                Safe gate data

                Uo≤ 28V Io≤ 93mA Po≤ 0.65W Co≥ Ci+Cc Lo≥ Li+Lc

                Explosion proof certificate number

                CE16.1206X